Calibration of X and Y axes.
If your device does not align correct you can make a spirit level calibration.
- Connect to your 2Dscanner.
- Place it on a relatively flat surface such as a desk or kitchen counter. Don’t worry if the surface is not perfectly flat.
- From the menu item “Tools” go to “Terminal”
- Press the “CALACC” button which is green in colour.

5. Wait about one minute until the process is complete. The 2Dscanner will rotate 90 degrees sequentially.
Calibration Z.
- Place the 2Dscanner vertically so that the Laser is facing the ceiling, on the edge of a table so that you can rotate it after 180 degrees exactly.

2.From the menu “Tools ” go to “Terminal”.
3. Press the CALACCZ button.

4. Wait 25sec until the device’s display writes

5. Rotate the 2Dscanner 180 degrees as shown in the picture and align it with the edge of the table. You have 15 sec.

6. Wait another 25sec until the process is complete.
If you have the version with Beeper then you will also hear auxiliary beeps during.
You can repeat the process if something goes wrong.